cabinet type
cardioid directivity in low frequencies
maximum SPL
122 dB peak / r = 1 m (3′3″)
frequency response
100 Hz … 20 kHz −6 dB
coverage angle f > 2 kHz
90° × 12° (H × V)
transducers
calibration
acoustic output level / PE = −14 dBu
95 dBSPL / r = 1 m (3′3″)
mains voltage
85 V … 260 V
power consumption
mains connectors
1× powercon
1× powercon loop-through output
amplifier type
2-channel PWM amplifier
nominal output power
2x 250 W
maximum output power
2x 500 W
noise level
≤ 9 dB (A) / r = 1 m (3′3″)
inputs
1× XLR analogue
1× XLR AES / EBU
input level
−6 dBu ... +6 dBu
outputs
1× XLR analogue
1× XLR AES / EBU
control inputs
1× RJ45 Ethernet
1× USB
electronic crossover frequency
2 kHz
directivity index
see diagram
equalizer
10 free programmable parametric EQs
delay
up to 1,000 ms
dimensions (h × w × d)
424 × 210 × 330 mm (16.7″ × 8.3″ × 13″)
weight
12.9 kg (28.4 lbs)
environmental specifications
design of the cabinet
lumber core plywood with scratch proof structure coating
black RAL9005, other colours on request
additional accessories (optional)
security lug
stand, wall and ceiling mount elements